Patented e-breathing
Micro active sampling isolates the air sample for higher accuracy in the field.
A continuous ambient air quality monitoring station of the class GOCEMS monitors — up to 9 gases plus particulates, noise and weather in one solar-powered, IP66 unit, reporting 24/7.

Sampling, power, connectivity and storage are all designed so a unit can sit on a fenceline for years and keep delivering data GOCEMS can trust.
Micro active sampling isolates the air sample for higher accuracy in the field.
Built-in calibration software; cloud calibration over the standby GSM link.
Certified enclosure rated for harsh, high-humidity and dusty conditions.
Runs 100% on solar for off-grid sites; LiFePO4 battery gives up to 24 h backup.
Firmware and configuration pushed from the server — no site visit required.
GSM / LTE / Wi-Fi / LoRa / NB-IoT / Satellite / Ethernet / Modbus.
Compact pole- or wall-mount unit that drops into existing infrastructure.
Up to 16 GB / 90 days of local storage so no data is lost if the link drops.
General purpose, smart campus
PM1, PM2.5, PM10, PM100, CO₂, CO, Noise, Light, UV, Temp, Humidity, Pressure
Extensive, smart cities
Lite set + SO₂, NO, NO₂, O₃
Critical, industrial fenceline
Smart set + H₂S, TSP (PM100)
As per project brief
Up to 9 gases + PM + T/H/P + noise, with optional wind, rain & vibration modules
| Parameter | Range | Resolution | Principle |
|---|---|---|---|
| PM1 / PM2.5 / PM10 / TSP | up to 5000 µg/m³ | 0.1 µg/m³ | Laser scattering |
| Carbon monoxide (CO) | 0–5 / 0–50 / 0–100 ppm | 0.01 ppm | Electrochemical |
| Carbon dioxide (CO₂) | 0–1000 / 0–5000 ppm | 0.75 ppm | NDIR |
| Nitric oxide (NO) | 0–5 / 0–100 ppm | 0.001 ppm | Electrochemical |
| Nitrogen dioxide (NO₂) | 0–10 / 0–100 ppm | 0.001 ppm | Electrochemical |
| Ozone (O₃) | 0–10 ppm | 0.001 ppm | Electrochemical |
| Hydrogen sulphide (H₂S) | 0–1.5 / 0–50 / 0–200 ppm | 0.001 ppm | Electrochemical |
| Sulphur dioxide (SO₂) | 0–10 / 0–100 ppm | 0.001 ppm | Electrochemical |
| Ambient noise | up to 140 dB | 1 dB | Acoustic |
| Temp / Humidity / Pressure | −40 to 125 °C · 0–100 %RH · 300–1100 hPa | 0.01 °C | Capacitive / resistive |
| Solar radiation & UV | up to 100,000 lux · UV index 0–12 | 0.1 lux | Photoconductivity |
External modules available: wind (anemometer), rain gauge and vibration sensors. Ranges vary by sensor option — figures are indicative, per the Polludrone datasheet V7.1, and are confirmed for each deployment.
Every unit is calibrated in an ISO/IEC 17025:2017 lab against NIST-traceable reference gases, following U.S. EPA guidelines.
Units are then run beside a reference station using U.S. EPA-designated FEM/FRM instruments to tune real-world response.
Once running in the field, units are calibrated on location with known-concentration cal gas or by collocating with a reference standard.
Stations like Polludrone stream into the GOCEMS cloud, where ECHT's monitoring service takes over — data validation, EPA-Ghana compliance dashboards, threshold alerts and one-click regulatory reports all run on top of that feed.
Polludrone is designed and manufactured by Oizom Instruments Pvt. Ltd. This page is a technical reference for the instrumentation GOCEMS monitors — ECHT Environmental Services operates the monitoring, validation and compliance service and does not sell or install monitoring hardware. Specifications are drawn from the Polludrone datasheet (V7.1) and are subject to change by the manufacturer.